Alive Air Air Purifier Owner's Manual Page 11

  • Download
  • Add to my manuals
  • Print
  • Page
    / 16
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 10
10
5. Air Dry all washed parts.ONLY
4. Cleaning the Washable Pre-Filter & Electronic Grid
Please do not clean using acidic or alkaline detergent that can create rust on the surface of device.
Place the two washable filters in the bathtub
Please take care not to damage any wiring while cleaning the electronic grid
If any electrical discharge wire is broken, the device will lose part or
all of its dust collecting capability.
Any broken wires should be thrown away instead of being left inside the unit.
Otherwise, a dangerous short-circuit or high-voltage sparks may occur.
Please contact for additional electrical discharge wire.[email protected]
Cleaning and Maintenance of Washable Pre-Filter & Electronic Grid (Cont.)
Put a very small amount of Dish Detergent such as Dawn in the bathtub.[ automatic dishwasher detergent]NOT
Plastic Wrap
Air dry the pre-filter, electronic grid and faceplate overnight. Operating
a wet unit may cause electrical shock or malfunction.
If the front cover of the electronic grid is not properly installed,
the unit will not function.
Please make sure the plastic wrap for the electrical discharge wire
is located in its proper position.
Alive Air 9-Stage Air Purifier Owner’s Manual
Fill the tub with warm water (not hot) to just cover the filters
Soak the two filters for a good half hour to remove dust and grime(Do Scrub)NOT
Drain the tub and rinse the filters under the shower head. Though the faceplate
does not need soaking, rinse both sides with the shower head as well.
6. if using AUTO SETTING, a New 'Clean Air Reference' is required after cleaningONLY
Every time you remove the faceplate to clean the unit, if there is a power outage, or you power it off, or if you unplug the unit for
any reason, you will have to re-program a 'reference for clean air' if you are leaving your machine on AUTO.
This is the case because any memorized content will have been completely erased. See page 6 for instructions on resetting
the auto-sensor.
Electronic Grid Wire Replacement
It’s unusual to break a grid wire if properly following the above instructions for cleaning the Electronic Grid. But, if it does happen, call
(800) 215-1689 to order a replacement wire(s). operate your air purifier until you’ve received and replaced the broken wire(s).Do NOT
~ CAUTION: The grid wire and spring ends may have sharp edges. Please, handle them with care. ~
The Electronic Grid should have 3 wires extending from a bottom 'hook', around the top and back down to another 'hook'. Place one spring
end on a bottom hook.
Wrap the wire with it's plastic coated center around the 3 pegs near the top of the grid assembly. Gently stretch the wire just enough to
place the spring end over the hook at the lower end of the grid assembly.
For additional visual instructions, see "Plasma Grid Wire Replacement" illustration at
http://aliveairpurifier.com/wp-content/uploads/2009/09/plasma-wire1.jpg
CLEANING AND MAINTENANCE
(